Warm flat roof building regulations in Ireland
Under Technical Guidance Document L (2022), a new flat roof or extension faces a 0.20 W/m²K statutory backstop (0.25 W/m²K on existing dwelling alterations). Fitting 120 to 150 mm foil-faced PIR above the 18 mm OSB3 deck reaches 0.15 to 0.18 W/m²K and eliminates cold-deck condensation.
Technical Guidance Document L (2022) U-values, PIR insulation thickness, condensation rules and planning exemptions for EPDM flat roofs.
Free, no obligation. One local roofer prices it, not five.
- 0.20 W/m²Knew dwelling & extension Part L ceiling
- 0.25 W/m²Kexisting flat roof upgrade threshold
- 0.15–0.18W/m²K reached by 120–150 mm PIR
- 40 m²Class 1 rear extension exempt cap

What TGD L (2022) requires for Irish flat roofs
Flat roofs over heated rooms in Ireland are governed by Part L of the Building Regulations (Technical Guidance Document L, Conservation of Fuel and Energy for Dwellings 2022, plus the matching 2022 non-domestic volume). While pitched roofs carry a 0.16 W/m²K ceiling, flat roofs carry a specific area-weighted backstop of 0.20 W/m²K on new builds and extensions, and 0.25 W/m²K when upgrading an existing roof element.
New dwelling or heated rear extension
- Statutory Part L target
- Max 0.20 W/m²K (TGD L Table 1)
- Practical EPDM warm-roof spec
- 120 to 150 mm foil-faced PIR reaches 0.15–0.18 W/m²K
Existing flat roof replacement / alteration
- Statutory Part L target
- Max 0.25 W/m²K (TGD L Table 5)
- Practical EPDM warm-roof spec
- 100 to 120 mm PIR above a taped VCL removes cold-deck rot
Non-domestic / commercial flat roof
- Statutory Part L target
- Max 0.20 W/m²K (TGD L 2022)
- Practical EPDM warm-roof spec
- 120 to 150 mm rigid PIR or tapered PIR cut to 1:60 fall
Unheated detached garage or porch
- Statutory Part L target
- Exempt from dwelling Part L thermal limit
- Practical EPDM warm-roof spec
- Cold-roof 1.14 mm or 1.52 mm EPDM on ventilated 18 mm OSB3
In practice, architects and BER assessors specify 120 mm to 150 mm of tissue- or foil-faced rigid PIR board (thermal conductivity 0.022 W/mK) over the structural deck so the roof achieves 0.15 to 0.18 W/m²K and passes whole-house DEAP energy targets comfortably. Check full build-up details on warm-roof EPDM with PIR.
Price my EPDM roof
Four quick taps and our fitted price shows before we ask for a phone number. One local roofer rings you, not five.
A rear extension EPDM flat roof, 26 to 45 m², warm roof with PIR insulation: €4,400 to €7,800, supplied and fitted.
How the price is worked out
The range reflects typical supply-and-fit EPDM rubber flat-roofing rates in Ireland including 13.5% VAT. Cold-roof figures cover stripping old felt, laying a 1.14 mm or 1.52 mm single-ply EPDM sheet with cold-applied adhesives, perimeter kerb and drip trims, and site clearance on a sound deck. Warm-roof figures add a vapour control layer and 120 to 150 mm foil-faced PIR insulation boards to meet Part L. Rotten 18 mm OSB3 deck boards, new rooflights, extensive leadwork or two-storey scaffolding are priced after inspecting the roof.
Condensation control, roof falls and planning limits
- Warm-roof build-up stops interstitial condensation. Placing the entire PIR insulation layer above the 18 mm OSB3 deck keeps the timber joists at room temperature all winter, eliminating the dew point inside the roof void.
- Minimum 1:40 design fall (BS 6229). Structural firrings or tapered PIR insulation ensure the finished roof holds at least a 1:80 slope even after timber deflection, preventing long-term ponding.
- 150 mm abutment upstand height. Check existing first-floor window sills before raising roof height by 140 mm with PIR; low sills sometimes need tapered perimeter edges or window adjustments.
- Planning exemption for roof replacement and rear extensions. Like-for-like re-covering with EPDM falls under Section 4(1)(h) maintenance. New single-storey rear extensions up to 40 m² are generally exempt under Class 1 provided 25 m² of rear garden remains.
Common questions on EPDM flat roofs
What is the Part L U-value limit for a flat roof in Ireland?
TGD L (2022) sets a 0.20 W/m²K area-weighted backstop for new flat roofs and extensions, and 0.25 W/m²K for alterations to existing flat roofs.
How thick does PIR insulation need to be under EPDM?
120 mm of rigid PIR (0.022 W/mK) delivers roughly 0.18 W/m²K, and 150 mm PIR brings the roof down to about 0.15 W/m²K, comfortably beating the 0.20 W/m²K cap.
Do I need planning permission to replace felt with EPDM rubber?
No, like-for-like flat roof replacement on a standard house is exempt maintenance unless the building is a Protected Structure or you raise the parapet height materially.
Does a garage flat roof have to meet Part L insulation rules?
Unheated detached garages and enclosed porches outside the house thermal envelope do not need warm-roof PIR, though insulating an integral garage beneath a bedroom is strongly advised.
Will raising a flat roof by 150 mm clash with upstairs window sills?
It can on older extensions with tight sill clearance. A flat roofer measures the height from existing deck to first-floor sill during the survey and can use thinner high-performance boards or tapered perimeters if needed.
All EPDM roofing pages and guides
EPDM systems
Specs & detailing

See your m² EPDM price before anyone calls
Pick the roof scope, rough area and cold or warm build-up. When you want a written price, your outline goes to a single flat roofer in your county.
