Warm-roof EPDM with rigid PIR insulation
A full warm flat roof with 18 mm OSB3 decking, vapour control layer, 120 to 150 mm rigid PIR insulation and 1.52 mm EPDM costs €130 to €190 per m² fitted in Ireland. A typical 26 to 45 m² rear extension runs €4,400 to €7,800.
The four-layer insulated flat roof build-up that beats Part L 0.20 W/m²K targets and keeps condensation out of your ceiling timber.
Free, no obligation. One local roofer prices it, not five.
- €130–€190/m²full warm-roof EPDM fitted
- 120–150 mmPIR thickness above deck
- 0.15–0.18W/m²K achieved U-value
- Zero air voideliminates cold-deck rot

The four layers of a compliant Irish warm EPDM roof
Older Irish extensions stuffed fibreglass wool between timber joists below the plywood deck. Moist kitchen air seeped upward, condensed against the freezing underside of the deck and rotted the roof from inside out. A warm flat roof moves every millimetre of insulation above the structural timber so the joists stay warm and dry year round.
- Layer 1: Structural 18 mm OSB3 tongue-and-groove deck. Screwed onto roof joists with 1:40 firring strips to create positive drainage toward the gutter or outlet.
- Layer 2: Taped Vapour Control Layer (VCL). Heavy-duty 1000-gauge polythene or self-adhesive aluminium-foil VCL laid across the OSB3, turned up 150 mm at walls and taped at every lap so steam cannot reach the PIR.
- Layer 3: 120 to 150 mm tissue-faced rigid PIR boards. Mechanically fixed with thermally broken tube washers or bonded in PU adhesive, staggered in brick-bond joints to prevent thermal bridging.
- Layer 4: Cold-applied 1.52 mm EPDM rubber membrane. Adhered directly to the tissue-faced PIR upper skin using water-based acrylic deck adhesive, with contact adhesive along perimeters and upstands.
Price my EPDM roof
Four quick taps and our fitted price shows before we ask for a phone number. One local roofer rings you, not five.
A warm-roof insulated EPDM system, 26 to 45 m², warm roof with PIR insulation: €4,400 to €7,800, supplied and fitted.
How the price is worked out
The range reflects typical supply-and-fit EPDM rubber flat-roofing rates in Ireland including 13.5% VAT. Cold-roof figures cover stripping old felt, laying a 1.14 mm or 1.52 mm single-ply EPDM sheet with cold-applied adhesives, perimeter kerb and drip trims, and site clearance on a sound deck. Warm-roof figures add a vapour control layer and 120 to 150 mm foil-faced PIR insulation boards to meet Part L. Rotten 18 mm OSB3 deck boards, new rooflights, extensive leadwork or two-storey scaffolding are priced after inspecting the roof.
PIR thickness, U-values and edge fascia depth
100 mm PIR (0.022 W/mK)
- Approximate U-value
- 0.21 W/m²K
- Part L fit & typical use
- Upgrading existing roofs under TGD L Table 5 (0.25 limit)
120 mm PIR (0.022 W/mK)
- Approximate U-value
- 0.18 W/m²K
- Part L fit & typical use
- Beats 0.20 W/m²K new-extension cap cleanly
150 mm PIR (0.022 W/mK)
- Approximate U-value
- 0.15 W/m²K
- Part L fit & typical use
- NZEB new extensions and high-BER retrofits
Tapered PIR (120–180 mm)
- Approximate U-value
- 0.15–0.17 W/m²K
- Part L fit & typical use
- Creates built-in 1:60 fall over flat concrete slabs
Adding 120 to 150 mm of PIR lifts the finished roof surface by roughly 145 mm. Your roofer extends the timber fascia edge or fits deeper uPVC fascia boards and deep-profile check kerb trims so the exterior roofline looks crisp and balanced. See Part L warm-roof building regulations.
Related EPDM guides
Warm-roof building regsTGD L 2022 flat-roof U-values (0.20 W/m²K new, 0.25 W/m²K existing) and Class 1 exemptions.
Cold vs warm flat roofsDew-point condensation physics, ventilated joist voids and Part L flat-roof U-values.
Extension EPDM flat roofsSingle-piece rubber sheets for Irish rear extensions, wall abutments and kitchen vapour control.
OSB3 deck prep & falls18 mm tongue-and-groove OSB3 boards, 1:40 firring strips and fixing soft spots.
EPDM roof costFull 2026 Irish per-m² price guide for cold roofs, warm PIR build-ups, decks and trims.
Parapet upstands & flashing150 mm upstand height, contact adhesive on vertical blockwork and Code-4 lead chases.Common questions on EPDM flat roofs
Can EPDM be glued directly to foil-faced PIR boards?
Standard water-based acrylic deck adhesive needs a porous surface to dry, so it must only be used on glass-tissue-faced PIR boards or an overlaid 18 mm OSB3 deck. Foil-faced PIR requires either tissue-faced roofing grade PIR or PU foaming adhesive with fleece-backed EPDM.
How much warmer does a kitchen extension feel after a warm roof upgrade?
Moving from an uninsulated or poorly vented cold flat roof (often 0.60 to 1.20 W/m²K) down to 0.15–0.18 W/m²K cuts roof heat loss by more than 75% and stops winter ceiling mould.
Do I need to vent the space between joists on a warm flat roof?
No. Once the full insulation layer sits above the VCL and OSB3 deck, the joist zone stays inside the warm envelope and is sealed tight rather than cross-ventilated.
Can tapered PIR boards fix a ponding concrete extension roof?
Yes. Pre-cut tapered PIR schemes add both thermal compliance and a clean 1:60 fall without stripping or screed-levelling a heavy concrete slab.
All EPDM roofing pages and guides
EPDM systems
Specs & detailing

See your m² EPDM price before anyone calls